Insulation Calculator
Insulation depth = target R-value ÷ R-value per inch. Reaching R-49 in a 40 × 30 ft attic with blown cellulose at about R-3.5 per inch takes 14 in. Over 1,200 sq ft plus 10% waste, that is 1,320 sq ft and about 1,540 cu ft of loose fill.
Insulation is specified by R-value, its resistance to heat flow, and each material delivers a different R per inch. This calculator works out how thick the layer must be to reach your target and how much area and loose-fill volume that means, so you can compare products and read coverage charts.
The formula
Depth (in) = target R ÷ R per inch
Area with waste = length × width × (1 + waste %)
Volume (cu ft) = area × depth ÷ 12 × (1 + waste %)
Coverage and yield assumptions
R per inch values are typical: blown fiberglass about R-2.2 to 2.9 (default 2.5), blown cellulose about 3.2–3.8 (default 3.5), fiberglass batts about 2.9–3.8, open-cell spray foam about 3.5–3.8 and closed-cell about 6–7, as summarized by the US Department of Energy. For loose fill, use the bag label coverage chart, which lists bags per 1,000 sq ft at each R-value and accounts for settling.
Recommended R-values
ENERGY STAR recommends attic insulation of R-30 to R-49 in the warmest US climate zones and R-49 to R-60 in most others when starting from little or no insulation. Adding to an existing 3–4 in layer usually targets R-38 to R-49 total. Walls are limited by cavity depth: 2×4 walls take R-13 to R-15 batts, 2×6 walls R-19 to R-21, and continuous exterior foam can add R-5 or more.
Batts vs loose fill
Batts fit standard stud and joist cavities at 16 or 24 in on center and are easy to handle in open walls and floors. Loose fill blown with a rented machine covers attics quickly and fills around wires, pipes and irregular framing. In attics, it is common to blow loose fill over existing batts. Spray foam air-seals and insulates in one step but is usually a professional job.
Air sealing first
The DOE recommends sealing air leaks before insulating: top plates, wiring holes, plumbing chases, recessed lights and the attic hatch. Air carries heat and moisture past insulation, so sealing often saves as much energy as the insulation itself. Keep insulation away from chimneys and non-IC-rated light fixtures, and install baffles at the eaves so soffit vents stay open.
Safety and comfort
- Wear a respirator, goggles, gloves and long sleeves.
- Walk only on joists or boards in the attic.
- Use depth rulers stapled to trusses to blow an even layer.
- Check for rebates from utilities and federal tax credits.
Common mistakes to avoid
- Insulating before sealing air leaks.
- Covering soffit vents, which traps moisture.
- Compressing batts, which lowers their R-value.
- Burying non-IC recessed lights or touching chimneys with insulation.
- Buying bags by area alone instead of the coverage chart for your R-value.
Waste factor
10% covers uneven depth and spillage. Use 5% for batts in open, standard cavities and 15% for loose fill over irregular framing or when you expect settling beyond the label's allowance.
Imperial and metric
Switch the toggle above the inputs to enter ft ↔ m. The page converts metric entries to imperial before calculating, using NIST factors (1 ft = 0.3048 m, 1 in = 2.54 cm), and shows key results in both systems.
Worked examples
Attic to R-49 with cellulose
Inputs: area length 40 ft; area width 30 ft; insulation type: Blown cellulose (~R-3.5/in); target r-value 49; waste factor 10%.
Result: Install about 14 inches over 1,320 sq ft.
- Units to buy (rounded up): 1,320 sq ft
- Area: 1,200 sq ft (111.5 m²)
- Area with waste: 1,320 sq ft (122.6 m²)
- Loose-fill volume: 1,540 cu ft
Attic to R-60 with fiberglass
Inputs: area length 50 ft; area width 28 ft; insulation type: Blown fiberglass (~R-2.5/in); target r-value 60; waste factor 10%; cost per unit $1.1.
Result: Install about 24 inches over 1,540 sq ft.
- Units to buy (rounded up): 1,541 sq ft
- Area: 1,400 sq ft (130.1 m²)
- Area with waste: 1,540 sq ft (143.1 m²)
- Loose-fill volume: 3,080 cu ft
- Estimated material cost: $1,695.10
Rim joist with closed-cell foam R-15
Inputs: area length 150 ft; area width 1 ft; insulation type: Closed-cell spray foam (~R-6.5/in); target r-value 15; waste factor 10%.
Result: Install about 2.3 inches over 165 sq ft.
- Units to buy (rounded up): 165 sq ft
- Area: 150 sq ft (13.9 m²)
- Area with waste: 165 sq ft (15.3 m²)
- Loose-fill volume: 32 cu ft
Quick reference for common sizes
The table repeats the first worked example at smaller and larger sizes, keeping every other setting the same, so you can see how the insulation calculator result scales.
| Inputs | Result |
|---|---|
| area length 20.0 ft; area width 15.0 ft; insulation type: Blown cellulose (~R-3.5/in); target r-value 49; waste factor 10% | Install about 14 inches over 330 sq ft |
| area length 30.0 ft; area width 22.5 ft; insulation type: Blown cellulose (~R-3.5/in); target r-value 49; waste factor 10% | Install about 14 inches over 743 sq ft |
| area length 60.0 ft; area width 45.0 ft; insulation type: Blown cellulose (~R-3.5/in); target r-value 49; waste factor 10% | Install about 14 inches over 2,970 sq ft |
| area length 80 ft; area width 60 ft; insulation type: Blown cellulose (~R-3.5/in); target r-value 49; waste factor 10% | Install about 14 inches over 5,280 sq ft |
| area length 120 ft; area width 90 ft; insulation type: Blown cellulose (~R-3.5/in); target r-value 49; waste factor 10% | Install about 14 inches over 11,880 sq ft |
Limitations
Real installed R-value depends on density, settling, compression and air leaks. Use the product's coverage chart for bag counts. Building codes set minimums by climate zone.
Frequently asked questions
How thick is R-49 insulation?
About 14 in of blown cellulose or 16–20 in of blown fiberglass.
What R-value should my attic have?
R-38 to R-60 in most US climate zones, per ENERGY STAR.
Can I add insulation on top of old insulation?
Yes, if it is dry and free of mold; unfaced insulation is best for the new layer.
Batts or blown-in for an attic?
Blown-in usually covers more evenly and fills gaps better in attics.
What insulation goes in a 2×4 wall?
R-13 or R-15 batts, or dense-pack cellulose.