Insulation Calculator

Insulation depth = target R-value ÷ R-value per inch. Reaching R-49 in a 40 × 30 ft attic with blown cellulose at about R-3.5 per inch takes 14 in. Over 1,200 sq ft plus 10% waste, that is 1,320 sq ft and about 1,540 cu ft of loose fill.

Units
Your result will appear here.

Insulation is specified by R-value, its resistance to heat flow, and each material delivers a different R per inch. This calculator works out how thick the layer must be to reach your target and how much area and loose-fill volume that means, so you can compare products and read coverage charts.

The formula

Depth (in) = target R ÷ R per inch

Area with waste = length × width × (1 + waste %)

Volume (cu ft) = area × depth ÷ 12 × (1 + waste %)

Coverage and yield assumptions

R per inch values are typical: blown fiberglass about R-2.2 to 2.9 (default 2.5), blown cellulose about 3.2–3.8 (default 3.5), fiberglass batts about 2.9–3.8, open-cell spray foam about 3.5–3.8 and closed-cell about 6–7, as summarized by the US Department of Energy. For loose fill, use the bag label coverage chart, which lists bags per 1,000 sq ft at each R-value and accounts for settling.

Recommended R-values

ENERGY STAR recommends attic insulation of R-30 to R-49 in the warmest US climate zones and R-49 to R-60 in most others when starting from little or no insulation. Adding to an existing 3–4 in layer usually targets R-38 to R-49 total. Walls are limited by cavity depth: 2×4 walls take R-13 to R-15 batts, 2×6 walls R-19 to R-21, and continuous exterior foam can add R-5 or more.

Batts vs loose fill

Batts fit standard stud and joist cavities at 16 or 24 in on center and are easy to handle in open walls and floors. Loose fill blown with a rented machine covers attics quickly and fills around wires, pipes and irregular framing. In attics, it is common to blow loose fill over existing batts. Spray foam air-seals and insulates in one step but is usually a professional job.

Air sealing first

The DOE recommends sealing air leaks before insulating: top plates, wiring holes, plumbing chases, recessed lights and the attic hatch. Air carries heat and moisture past insulation, so sealing often saves as much energy as the insulation itself. Keep insulation away from chimneys and non-IC-rated light fixtures, and install baffles at the eaves so soffit vents stay open.

Safety and comfort

Common mistakes to avoid

Waste factor

10% covers uneven depth and spillage. Use 5% for batts in open, standard cavities and 15% for loose fill over irregular framing or when you expect settling beyond the label's allowance.

Imperial and metric

Switch the toggle above the inputs to enter ft ↔ m. The page converts metric entries to imperial before calculating, using NIST factors (1 ft = 0.3048 m, 1 in = 2.54 cm), and shows key results in both systems.

Worked examples

Attic to R-49 with cellulose

Inputs: area length 40 ft; area width 30 ft; insulation type: Blown cellulose (~R-3.5/in); target r-value 49; waste factor 10%.

Result: Install about 14 inches over 1,320 sq ft.

Attic to R-60 with fiberglass

Inputs: area length 50 ft; area width 28 ft; insulation type: Blown fiberglass (~R-2.5/in); target r-value 60; waste factor 10%; cost per unit $1.1.

Result: Install about 24 inches over 1,540 sq ft.

Rim joist with closed-cell foam R-15

Inputs: area length 150 ft; area width 1 ft; insulation type: Closed-cell spray foam (~R-6.5/in); target r-value 15; waste factor 10%.

Result: Install about 2.3 inches over 165 sq ft.

Quick reference for common sizes

The table repeats the first worked example at smaller and larger sizes, keeping every other setting the same, so you can see how the insulation calculator result scales.

InputsResult
area length 20.0 ft; area width 15.0 ft; insulation type: Blown cellulose (~R-3.5/in); target r-value 49; waste factor 10%Install about 14 inches over 330 sq ft
area length 30.0 ft; area width 22.5 ft; insulation type: Blown cellulose (~R-3.5/in); target r-value 49; waste factor 10%Install about 14 inches over 743 sq ft
area length 60.0 ft; area width 45.0 ft; insulation type: Blown cellulose (~R-3.5/in); target r-value 49; waste factor 10%Install about 14 inches over 2,970 sq ft
area length 80 ft; area width 60 ft; insulation type: Blown cellulose (~R-3.5/in); target r-value 49; waste factor 10%Install about 14 inches over 5,280 sq ft
area length 120 ft; area width 90 ft; insulation type: Blown cellulose (~R-3.5/in); target r-value 49; waste factor 10%Install about 14 inches over 11,880 sq ft

Limitations

Real installed R-value depends on density, settling, compression and air leaks. Use the product's coverage chart for bag counts. Building codes set minimums by climate zone.

Frequently asked questions

How thick is R-49 insulation?

About 14 in of blown cellulose or 16–20 in of blown fiberglass.

What R-value should my attic have?

R-38 to R-60 in most US climate zones, per ENERGY STAR.

Can I add insulation on top of old insulation?

Yes, if it is dry and free of mold; unfaced insulation is best for the new layer.

Batts or blown-in for an attic?

Blown-in usually covers more evenly and fills gaps better in attics.

What insulation goes in a 2×4 wall?

R-13 or R-15 batts, or dense-pack cellulose.

Sources

  1. US Department of Energy, Energy Saver. Insulation. https://www.energy.gov/energysaver/insulation
  2. ENERGY STAR. Recommended home insulation R-values. https://www.energystar.gov/saveathome/seal_insulate/identify-problems-you-want-fix/diy-checks-inspections/insulation-r-values
  3. International Code Council. 2021 International Residential Code (IRC). https://codes.iccsafe.org/content/IRC2021P2

Method details: how we calculate.